Quality Guide

FDA QMSR vs ISO 13485: What Changed Since 2 February 2026

The FDA now builds its quality system rule on ISO 13485:2016. For most manufacturers that is a simplification, but the details of what FDA still adds, and what it can now inspect, decide whether your quality system is ready.

Reviewed by Aakash Jindal, Founder, iMDR MedTech. Regulatory status is checked and dated on each guide.

Side by Side

The Former QSR and the QMSR

TopicBefore 2 February 2026 (QSR)From 2 February 2026 (QMSR)
BasisFDA’s own set of quality system requirements in 21 CFR Part 82021 CFR Part 820 incorporating ISO 13485:2016 by reference, with ISO 9000:2015 clause 3 for terms and definitions
Conflicts with the lawNot applicableIf an ISO 13485 clause conflicts with the FD&C Act or FDA regulations, the Act and regulations control
Risk managementAddressed mainly in design controlsSpecifically required, in line with the standard’s risk-based approach across the quality system
Record termsDevice master record, design history file, device history recordISO 13485 terminology, including the medical device file
Management review and audit reportsExcluded from routine FDA inspection; management could certify they were doneFDA may inspect management review, quality audit and supplier audit reports
Inspection methodQuality System Inspection TechniqueCompliance Program 7382.850, which integrates the QMSR

Based on FDA’s QMSR page and FAQ as checked on 28 November 2026. Read the regulation and FDA’s current guidance before changing procedures.

Readiness

How to Prepare Your Quality System

Map your QMS to ISO 13485:2016 and to Part 820

Build a clause-by-clause map. Where you already hold an ISO 13485 certificate, find the FDA-specific items the standard does not spell out, such as complaint files, labelling and UDI, and the CGMP exemptions that still carry complaint and record duties.

Update procedures and templates

Remove outdated references to QSR terms and align record names with the standard. Keep the change list so an inspector can see what you changed and why.

Bring management review and audit records to inspection standard

Schedule, minutes, findings and follow-up should be complete and consistent. Treat supplier audit reports the same way.

Show risk management across the system

Link risk management to design, production, purchasing, complaints and change control, not only to the design file.

Rehearse an inspection

Run a mock inspection against Compliance Program 7382.850. Practise retrieving records quickly and explaining decisions.

Keep one system for several markets

An ISO 13485 base serves the EU MDR quality management system requirement as well. Document the market-specific layers so the system does not split into parallel versions.

One Quality System, Several Markets

The most useful result of the QMSR is alignment. A single ISO 13485-based system can serve the US, the EU and other markets that reference the standard, with market-specific additions. See the FDA vs EU MDR comparison and the five-country comparison for how the layers differ.

Alignment does not remove the need to know the differences. Treat the FDA-specific requirements as a checklist that sits on top of the standard, and keep it current.

FAQ

Frequently Asked Questions

What is the FDA QMSR?

The Quality Management System Regulation is the amended 21 CFR Part 820. It incorporates ISO 13485:2016 by reference and took effect on 2 February 2026, replacing the former Quality System Regulation. It applies to finished device manufacturers that intend to commercially distribute devices in the US, and to accessory manufacturers.

Does an ISO 13485 certificate mean I comply with the QMSR?

Not by itself. The QMSR incorporates ISO 13485, but it adds FDA requirements, and where the standard conflicts with the Federal Food, Drug, and Cosmetic Act or FDA regulations, the Act and regulations control. A certificate also does not replace an FDA inspection.

Are management review and internal audit records now open to FDA?

Yes. FDA has stated that the QMSR gives it authority to inspect management review, quality audit and supplier audit reports, and that the exceptions that existed in the former regulation were not kept. Have these records available and in good order.

How does FDA inspect under the QMSR?

FDA stopped using the Quality System Inspection Technique and uses the updated Compliance Program 7382.850, Inspection of Medical Device Manufacturers, which integrates the QMSR requirements.

Did the Device Master Record and Device History Record disappear?

The terms were replaced by ISO 13485 concepts such as the medical device file. You still must keep the records that show the device was designed, made and released as intended. Check your procedures and templates for outdated terms and for gaps against the standard’s record requirements.

Need a QMSR Gap Assessment or Mock Inspection?

Share your certifications, products and markets. Matching quality experts are put forward after team review.

Last updated: